Product Identification
Product ID:GACOFLEX UB-64 PART A
MSDS Date:01/01/1990
FSC:8010
NIIN:00N042082
Kit Part:Y
MSDS Number: BSTBM
Responsible Party
TUKWILA, WA 98188
US
Emergency Phone: 206-575-0450;800-424-9300(CHEMTREC)
Info Phone: 206-575-0450
Cage: 09463
Contractor
Telephone: 206-575-0450
Cage: 09463
Ingredients
70.
CAS: 78-93-3
RTECS: EL6475000
Fraction By Weight: <5%
OSHA PEL 200 PPM;300 PPM STEL
ACGIH TLV: 200 PPM;300 PPM STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
6.
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 12.4%
OSHA PEL 100 PPM;150 PPM STEL
ACGIH TLV: 100 PPM;150 PPM STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
22.
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: <5%
OSHA PEL 100 PPM;150 PPM STEL
ACGIH TLV: 50 PPM, S
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION OF HIGH CONCENTRATIONS CAN
PRODUCE CNS DEPRESSION. SKIN CONTACT CAN CAUSE SEVERE IRRITATION,
POSSIBLE BURNS, DEFATTING AND DERMATITIS. EYE CONTACT CAUSES SEVERE
IRRITATION, REDNESS, TEARING AND BLURRED VISION. NOTE: TOLUENE,
108-88-3, APPEARS ON NAVY LISTING OF OCCUPATIONAL CHEMICAL REPROD
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HEALTH HAZARDS: HAZARDS. SEEK CONSULTATION FROM
APPROPRIATE HEALTH PROFESSIONALS CONCERNING LATEST HAZARD LIST
INFORMATION AND SAFE HANDLING AND EXPOSURE INFORMATION .
Medical Cond Aggravated by Exposure:RPTD EXPOS CAN CAUSE ALLERGIC
REACTION WITH DEVELOPMENT OF OCCUPATIONAL ASTHMA. LONG TERM
EXPOSURE TO LOW VAP CONCS MAY CAUSE CHRONICALLY PROGRESSIVE PULM
DISEASE. RPTD SKIN CONT CAN RSLT IN SENSIT.
First Aid
First Aid:INHALATION: REMOVE TO FRESH AIR AND IF BREATHING HAS STOPPED,
GIVE ARTIFICIAL RESPIRATION. EYE: FLUSH IMMEDIATELY WITH WATER FOR
AT LEAST 15 MINUTES AND CALL PHYSICIAN AS SOON AS POSSIBLE. SKIN:
WASH WITH SOAP AND WATER AND REMOVE CONTAMINATED CLOTHING.
INGESTION: SEE PHYSICIAN AS SOON AS POSSIBLE.
Fire Fighting
Flash Point Method:TCC
Flash Point:20F,-6.7C
Lower Limits:1%
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL OR WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. COOL CNTNRS W/WATER FOG TO PVNT RUPTURE. BOILOVER MAY OCCUR WHEN
TEMP OF MATL APPROACHES BOILING (SUPDAT)
Unusual Fire/Explosion Hazard:SPILLS/VAP LEAKS READILY FROM FLAMM MIX
AT/ABOVE FLASH POINT. IT IS UNLIKELY THAT PROD WILL EXPLO DUE TO
MECH IMPACT BUT FIRE OR EXPLO MAY OCCUR FROM (SUPDAT)
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. KEEP PEOPLE
AWAY. AVOID BREATHING VAPORS. RECOVER FREE LIQUID AND ADD ABSORBENT
TO REMAINDER OF SPILL BEFORE COLLECTING WITH NON-SPARKING TOOLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP CONTAINERS CLOSED AND STORE IN
COOL DRY PLACE WITH ADEQUATE EXPLOSION PROOF VENTILATION. KEEP AWAY
FROM HEAT, SPARKS AND OPEN FLAME.
Other Precautions:GROUND EQUIPMENT TO PREVENT ACCUMULATION OF STATIC
CHARGE.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED ORGANIC VAPOR CANNISTERS
FOR LOW CONCENTRATIONS. USE NIOSH/MSHA APPROVED SELF-CONTAINED
BREATHING APPARATUS IN ENCLOSED AREAS INVOLVING HIGHER VAPOR
CONCENTRATIONS.
Ventilation:EXPLOSION PROOF MECHANICAL EQUIPMENT CAPABLE OF KEEPING
VAPOR CONCENTRATION BELOW TLV.
Protective Gloves:CHEM RESISTANT PLASTIC OR RUBB GLOVES.
Eye Protection:ANSI APPROVED CHEMICAL (WORK HYGIENE)
Other Protective Equipment:EYE BATH AND SAFETY SHOWER WHICH MEET ANSI
DESIGN CRITERIA SHOULD BE AVAILABLE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER. EYE PROTECTION:
GOGGLES AND FULL LENGTH FACESHIELD .
Supplemental Safety and Health
EXPLOSION HAZARDS: STATIC ACCUMULATION AND DISCHARGE. FIRE FIGHT
PROCEDURES: POINT OF SOLVENT. DO NOT EXTINGUISH FLAME AT LEAK
BECAUSE POSSIBILITY OF UNCONTROLLED EXPLOSIVE REIGNITION EXISTS.
CUT OF F UEL AND/OR ALLOW FIRE TO BURN OUT. EXTINGUISH RESIDUAL
FIRES WITH CHEMICAL POWDER OR FOAM.
Chemical Properties
HCC:F3
Boiling Pt:B.P. Text:>172F,>78C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.62
Evaporation Rate & Reference:SLOWER (ETHER=1)
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:31.3
Stability
Stability Indicator/Materials to Avoid:YES
AVOID STRONG OXIDIZING MATERIALS LIKE LIQUID CHLORINE AND CONCENTRATED
OXYGEN.
Stability Condition to Avoid:HEAT, SPARKS AND OPEN FLAME.
Hazardous Decomposition Products:INCOMPLETE BURNING MAY PRODUCE CARBON
MONOXIDE AND/OR CARBON DIOXIDE.
Disposal
Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH LOCAL, STATE, AND
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.